Alert Center
Failed QC, shifts, trends, high CV, analyzer drift, unresolved corrective actions, and decision-support signals.
Filters
Elevated CV% on Thyroid Stimulating Hormone (L2)
high cv
warning
Observed CV 8.63% exceeds expected range.
Immunoassay · Immuno I1 · 9/24/2026, 9:39:00 AM
Suggested possible causes
- Probe or pipette imprecision
- Temperature control instability
- Sample handling variability
Shift detected on Troponin I (L1)
shift
warning
Six consecutive results on the same side of the mean.
Immunoassay · Immuno I1 · 9/24/2026, 9:39:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Early-warning: possible drift on Thyroid Stimulating Hormone
predictive
info
Decision support
Mean shift of 1.48 SD over the trailing window. Decision-support signal only.
Immunoassay · Immuno I1 · 9/24/2026, 9:39:00 AM
Suggested possible causes
- Reagent approaching end of stability
- Calibration expiring in the next 72 hours
- Environmental temperature trending upward
- Control material degradation
Shift detected on Sodium (L1)
shift
warning
Six consecutive results on the same side of the mean.
Clinical Chemistry · Chem Analyzer A2 · 9/24/2026, 9:33:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Elevated CV% on Potassium (L1)
high cv
warning
Observed CV 3.44% exceeds expected range.
Clinical Chemistry · Chem Analyzer A2 · 9/24/2026, 9:30:00 AM
Suggested possible causes
- Probe or pipette imprecision
- Temperature control instability
- Sample handling variability
Early-warning: possible drift on Prothrombin Time
predictive
info
Decision support
Mean shift of 1.65 SD over the trailing window. Decision-support signal only.
Coagulation · Coag-One C1 · 9/24/2026, 8:35:00 AM
Suggested possible causes
- Reagent approaching end of stability
- Calibration expiring in the next 72 hours
- Environmental temperature trending upward
- Control material degradation
MIC Ceftriaxone Control failed QC (L1)
failed qc
critical
Violations: 1-3s, shift, 10x on MIC-CTX
Microbiology (Quantitative) · Micro M1 · 9/24/2026, 8:32:00 AM
Shift detected on MIC Ceftriaxone Control (L1)
shift
warning
Six consecutive results on the same side of the mean.
Microbiology (Quantitative) · Micro M1 · 9/24/2026, 8:32:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Alanine Aminotransferase failed QC (L2)
failed qc
critical
Violations: shift, 10x on ALT
Clinical Chemistry · Chem Analyzer A1 · 9/24/2026, 8:20:00 AM
Shift detected on Alanine Aminotransferase (L2)
shift
warning
Six consecutive results on the same side of the mean.
Clinical Chemistry · Chem Analyzer A1 · 9/24/2026, 8:20:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Early-warning: possible drift on Latex Agglutination Control
predictive
info
Decision support
Mean shift of 1.60 SD over the trailing window. Decision-support signal only.
Microbiology (Quantitative) · Micro M1 · 9/24/2026, 8:20:00 AM
Suggested possible causes
- Reagent approaching end of stability
- Calibration expiring in the next 72 hours
- Environmental temperature trending upward
- Control material degradation
Platelets failed QC (L1)
failed qc
critical
Violations: 4-1s, shift on PLT
Hematology · Hema-Line H1 · 9/24/2026, 7:35:00 AM
Shift detected on Platelets (L1)
shift
warning
Six consecutive results on the same side of the mean.
Hematology · Hema-Line H1 · 9/24/2026, 7:35:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Shift detected on Platelets (L2)
shift
warning
Six consecutive results on the same side of the mean.
Hematology · Hema-Line H1 · 9/24/2026, 7:35:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Hemoglobin failed QC (L1)
failed qc
critical
Violations: shift, 10x on HGB
Hematology · Hema-Line H1 · 9/24/2026, 7:27:00 AM
Shift detected on Hemoglobin (L1)
shift
warning
Six consecutive results on the same side of the mean.
Hematology · Hema-Line H1 · 9/24/2026, 7:27:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material
Hemoglobin failed QC (L2)
failed qc
critical
Violations: 1-3s, 2-2s, 4-1s, shift, 10x on HGB
Hematology · Hema-Line H1 · 9/24/2026, 7:27:00 AM
Shift detected on Hemoglobin (L2)
shift
warning
Six consecutive results on the same side of the mean.
Hematology · Hema-Line H1 · 9/24/2026, 7:27:00 AM
Suggested possible causes
- Reagent lot change without recalibration
- Environmental temperature drift
- Aging calibrator material